<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>fototerapia - Wyposażenie medyczne, Narzędzia chirurgiczne</title>
	<atom:link href="https://medleader.pl/tag/fototerapia/feed/" rel="self" type="application/rss+xml" />
	<link>https://medleader.pl/tag/fototerapia/</link>
	<description></description>
	<lastBuildDate>Tue, 24 Feb 2026 09:57:36 +0000</lastBuildDate>
	<language>pl-PL</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://medleader.pl/wp-content/uploads/2025/03/favicon2-100x100.png</url>
	<title>fototerapia - Wyposażenie medyczne, Narzędzia chirurgiczne</title>
	<link>https://medleader.pl/tag/fototerapia/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>OKULARKI DO FOTOTERAPII EYEMAX 2 &#8211; MAXTEC</title>
		<link>https://medleader.pl/okularki-do-fototerapii-eyemax-2-maxtec/</link>
		
		<dc:creator><![CDATA[lukasz]]></dc:creator>
		<pubDate>Wed, 29 Apr 2020 08:19:41 +0000</pubDate>
				<category><![CDATA[Drobny sprzęt medyczny]]></category>
		<category><![CDATA[Neonatologia]]></category>
		<category><![CDATA[Strona główna sekcja 2]]></category>
		<category><![CDATA[eyemax]]></category>
		<category><![CDATA[fototerapia]]></category>
		<category><![CDATA[okularki do fototerapii]]></category>
		<category><![CDATA[okularki do fototerapii bilirubinowej]]></category>
		<category><![CDATA[okularki Y]]></category>
		<category><![CDATA[opaski ochronne do fototerapii]]></category>
		<guid isPermaLink="false">http://medleader.pl/?p=1213</guid>

					<description><![CDATA[<p>Okularki do fototerapii EyeMax 2 bez lateksu, zapewniają optymalny komfort i ochronę pacjentów podczas zabiegów fototerapii. Jednoczęściowa, Y - kształtna, konstrukcja ma dwa punkty mocowania, które można regulować niezależnie; zapobiega to niechcianym ruchom i pozwala na idealne dopasowanie. Specjalna podkładka chroniąca oczy przed światłem ultrafioletowym została ergonomicznie zaprojektowana, aby zapobiegać wyciekom światła.</p>
<p>Artykuł <a href="https://medleader.pl/okularki-do-fototerapii-eyemax-2-maxtec/">OKULARKI DO FOTOTERAPII EYEMAX 2 &#8211; MAXTEC</a> pochodzi z serwisu <a href="https://medleader.pl">Wyposażenie medyczne, Narzędzia chirurgiczne</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1>EyeMax 2</h1>
<p style="text-align: justify;"><img fetchpriority="high" decoding="async" class="size-medium wp-image-1217 alignleft" src="https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-application-medium-242x300.jpg" alt="" width="242" height="300" srcset="https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-application-medium-242x300.jpg 242w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-application-medium-121x150.jpg 121w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-application-medium-600x745.jpg 600w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-application-medium.jpg 765w" sizes="(max-width: 242px) 85vw, 242px" /></p>
<p style="text-align: justify;">EyeMax 2 to maska ​​ochronna na oczy dla niemowląt, przeznaczona do zakładania ochronnie podczas fototerapii; jest to standardowy środek do leczenia żółtaczki. Ergonomiczne dopasowanie sprawia, że ​​EyeMax 2 pozostaje na swoim miejscu, nawet gdy pacjent się porusza. Wszystkie rozmiary można łatwo regulować, aby bezpiecznie i wygodnie przylegały do ​​głowy pacjenta, od najmniejszych wcześniaków po donoszone niemowlęta. EyeMax 2, bez żadnych klejów ani materiałów drażniących skórę, to wygodna opcja, która pomaga chronić oczy pacjenta przed szkodliwym działaniem promieniowania UV.</p>
<p style="text-align: justify;">Okularki do fototerapii EyeMax 2 bez lateksu, zapewniają optymalny komfort i ochronę pacjentów podczas zabiegów fototerapii. Jednoczęściowa, Y – kształtna, konstrukcja ma dwa punkty mocowania, które można regulować niezależnie; zapobiega to niechcianym ruchom i pozwala na idealne dopasowanie. Specjalna podkładka chroniąca oczy przed światłem ultrafioletowym została ergonomicznie zaprojektowana, aby zapobiegać wyciekom światła.</p>
<p>– Regulowany pasek dla optymalnego komfortu</p>
<p>– Większa podkładka pod oczy dla mniejszego nacisku i lepszej ochrony przed promieniowaniem UV</p>
<p>– Bez lateksu</p>
<p style="text-align: justify;">Okularki do fototerapii EyeMax 2 bez lateksu, zapewniają optymalny komfort i ochronę pacjentów podczas zabiegów fototerapii. Jednoczęściowa, Y &#8211; kształtna, konstrukcja ma dwa punkty mocowania, które można regulować niezależnie; zapobiega to niechcianym ruchom i pozwala na idealne dopasowanie. Specjalna podkładka chroniąca oczy przed światłem ultrafioletowym została ergonomicznie zaprojektowana, aby zapobiegać wyciekom światła.</p>
<p>&#8211; Regulowany pasek dla optymalnego komfortu</p>
<p>&#8211; Większa podkładka pod oczy dla mniejszego nacisku i lepszej ochrony przed promieniowaniem UV</p>
<p>&#8211; Bez lateksu</p>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 25%;"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1214" src="https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium-300x214.jpg" alt="" width="300" height="214" srcset="https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium-300x214.jpg 300w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium-1024x731.jpg 1024w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium-768x548.jpg 768w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium-150x107.jpg 150w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium-400x284.jpg 400w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium-1080x771.jpg 1080w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium-600x429.jpg 600w, https://medleader.pl/wp-content/uploads/2020/04/R300P01-eyemax2-regular-front-medium.jpg 1200w" sizes="(max-width: 300px) 85vw, 300px" /></td>
<td style="width: 25%;">EyeMax 2 Regular</td>
<td style="width: 25%;">R300P01</td>
<td style="width: 25%;">32cm &#8211; 38cm</td>
</tr>
<tr>
<td style="width: 25%;"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1215" src="https://medleader.pl/wp-content/uploads/2020/04/R300P02-eyemax2-preemie-front-medium-300x239.jpg" alt="" width="300" height="239" srcset="https://medleader.pl/wp-content/uploads/2020/04/R300P02-eyemax2-preemie-front-medium-300x239.jpg 300w, https://medleader.pl/wp-content/uploads/2020/04/R300P02-eyemax2-preemie-front-medium-1024x816.jpg 1024w, https://medleader.pl/wp-content/uploads/2020/04/R300P02-eyemax2-preemie-front-medium-768x612.jpg 768w, https://medleader.pl/wp-content/uploads/2020/04/R300P02-eyemax2-preemie-front-medium-150x120.jpg 150w, https://medleader.pl/wp-content/uploads/2020/04/R300P02-eyemax2-preemie-front-medium-1080x861.jpg 1080w, https://medleader.pl/wp-content/uploads/2020/04/R300P02-eyemax2-preemie-front-medium-600x478.jpg 600w, https://medleader.pl/wp-content/uploads/2020/04/R300P02-eyemax2-preemie-front-medium.jpg 1192w" sizes="(max-width: 300px) 85vw, 300px" /></td>
<td style="width: 25%;">EyeMax 2 Preemie</td>
<td style="width: 25%;">R300P02</td>
<td style="width: 25%;">26,5cm &#8211; 32cm</td>
</tr>
<tr>
<td style="width: 25%;"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1216" src="https://medleader.pl/wp-content/uploads/2020/04/R300P03-eyemax2-micro-front-medium-300x232.jpg" alt="" width="300" height="232" srcset="https://medleader.pl/wp-content/uploads/2020/04/R300P03-eyemax2-micro-front-medium-300x232.jpg 300w, https://medleader.pl/wp-content/uploads/2020/04/R300P03-eyemax2-micro-front-medium-1024x791.jpg 1024w, https://medleader.pl/wp-content/uploads/2020/04/R300P03-eyemax2-micro-front-medium-768x593.jpg 768w, https://medleader.pl/wp-content/uploads/2020/04/R300P03-eyemax2-micro-front-medium-150x116.jpg 150w, https://medleader.pl/wp-content/uploads/2020/04/R300P03-eyemax2-micro-front-medium-1080x834.jpg 1080w, https://medleader.pl/wp-content/uploads/2020/04/R300P03-eyemax2-micro-front-medium-600x464.jpg 600w, https://medleader.pl/wp-content/uploads/2020/04/R300P03-eyemax2-micro-front-medium.jpg 1200w" sizes="(max-width: 300px) 85vw, 300px" /></td>
<td style="width: 25%;">EyeMax 2 Micro</td>
<td style="width: 25%;">R300P03</td>
<td style="width: 25%;">20cm &#8211; 26,5cm</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1219" src="https://medleader.pl/wp-content/uploads/2020/04/R300P02-20-eyemax-preemie-20-pack-small-280x300.jpg" alt="" width="280" height="300" srcset="https://medleader.pl/wp-content/uploads/2020/04/R300P02-20-eyemax-preemie-20-pack-small-280x300.jpg 280w, https://medleader.pl/wp-content/uploads/2020/04/R300P02-20-eyemax-preemie-20-pack-small-140x150.jpg 140w, https://medleader.pl/wp-content/uploads/2020/04/R300P02-20-eyemax-preemie-20-pack-small.jpg 559w" sizes="(max-width: 280px) 85vw, 280px" /> <img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1220" src="https://medleader.pl/wp-content/uploads/2020/04/R300P03-20-eyemax-micro-20-pack-small-280x300.jpg" alt="" width="280" height="300" srcset="https://medleader.pl/wp-content/uploads/2020/04/R300P03-20-eyemax-micro-20-pack-small-280x300.jpg 280w, https://medleader.pl/wp-content/uploads/2020/04/R300P03-20-eyemax-micro-20-pack-small-140x150.jpg 140w, https://medleader.pl/wp-content/uploads/2020/04/R300P03-20-eyemax-micro-20-pack-small.jpg 559w" sizes="(max-width: 280px) 85vw, 280px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Artykuł <a href="https://medleader.pl/okularki-do-fototerapii-eyemax-2-maxtec/">OKULARKI DO FOTOTERAPII EYEMAX 2 &#8211; MAXTEC</a> pochodzi z serwisu <a href="https://medleader.pl">Wyposażenie medyczne, Narzędzia chirurgiczne</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lampa LED do fototerapii noworodków</title>
		<link>https://medleader.pl/ofn-02-lampa-mobilna-do-fototerapii/</link>
		
		<dc:creator><![CDATA[Lambar]]></dc:creator>
		<pubDate>Thu, 14 Feb 2019 09:02:41 +0000</pubDate>
				<category><![CDATA[Inne urządzenia medyczne]]></category>
		<category><![CDATA[Neonatologia]]></category>
		<category><![CDATA[Strona główna sekcja 1]]></category>
		<category><![CDATA[Urządzenia medyczne]]></category>
		<category><![CDATA[fototerapia]]></category>
		<category><![CDATA[lampa do fototerapii]]></category>
		<category><![CDATA[lampa LED do fototerapii]]></category>
		<category><![CDATA[łóżeczkowa lampa do fototerapii]]></category>
		<category><![CDATA[mobilna lampa do fototerapii]]></category>
		<guid isPermaLink="false">http://medleader.pl/?p=699</guid>

					<description><![CDATA[<p>Mobilna lampa do fototerapii, do skutecznego leczenia żółtaczki noworodków. Lampa do fototerapii stosowana do leczenia wysokich stężeń bilirubiny. Dwie wersje mobilna lampa do fototerapii oraz do postawienia na inkubator.</p>
<p>Artykuł <a href="https://medleader.pl/ofn-02-lampa-mobilna-do-fototerapii/">Lampa LED do fototerapii noworodków</a> pochodzi z serwisu <a href="https://medleader.pl">Wyposażenie medyczne, Narzędzia chirurgiczne</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1>LED Lampa do fototerapii</h1>
<ul>
<li><img loading="lazy" decoding="async" class=" wp-image-1339 alignleft" src="https://medleader.pl/wp-content/uploads/2019/02/118879-19853105-300x291.jpg" alt="" width="325" height="316" srcset="https://medleader.pl/wp-content/uploads/2019/02/118879-19853105-300x291.jpg 300w, https://medleader.pl/wp-content/uploads/2019/02/118879-19853105-150x146.jpg 150w, https://medleader.pl/wp-content/uploads/2019/02/118879-19853105.jpg 500w" sizes="(max-width: 325px) 85vw, 325px" />3.5&#8243; dotykowy ekran</li>
<li>16 super niebieskie LED i 4 białe LED diody</li>
<li>Żywotność: 50,000 godzin</li>
<li>Regulowana intensywność naświetlania (I, II, III)</li>
<li>0-999h timer 48h odliczanie w dół</li>
<li>Real-time zegar i data</li>
<li>Nie nagrzewa się, nie emituje UV, i IR</li>
<li>360° obracana głowica lampy, wygodne pozycjonowani</li>
<li>w wersji na mobilnym statywie oraz z uchwytem do inkubatora</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignnone  wp-image-1338" src="https://medleader.pl/wp-content/uploads/2019/02/2222-300x212.png" alt="" width="231" height="163" srcset="https://medleader.pl/wp-content/uploads/2019/02/2222-300x212.png 300w, https://medleader.pl/wp-content/uploads/2019/02/2222-150x106.png 150w, https://medleader.pl/wp-content/uploads/2019/02/2222-400x284.png 400w, https://medleader.pl/wp-content/uploads/2019/02/2222.png 450w" sizes="(max-width: 231px) 85vw, 231px" /> <img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1340" src="https://medleader.pl/wp-content/uploads/2019/02/122959115-174838390937467-5403530945250095680-n-300x251.jpg" alt="" width="300" height="251" srcset="https://medleader.pl/wp-content/uploads/2019/02/122959115-174838390937467-5403530945250095680-n-300x251.jpg 300w, https://medleader.pl/wp-content/uploads/2019/02/122959115-174838390937467-5403530945250095680-n-768x643.jpg 768w, https://medleader.pl/wp-content/uploads/2019/02/122959115-174838390937467-5403530945250095680-n-150x126.jpg 150w, https://medleader.pl/wp-content/uploads/2019/02/122959115-174838390937467-5403530945250095680-n-600x502.jpg 600w, https://medleader.pl/wp-content/uploads/2019/02/122959115-174838390937467-5403530945250095680-n.jpg 1014w" sizes="(max-width: 300px) 85vw, 300px" /> </p>
<h3>Specyfikacja techniczna</h3>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 50%;">Źródło światła</td>
<td style="width: 50%;">16 diód super LED</td>
</tr>
<tr>
<td style="width: 50%;">Światło doświetlające</td>
<td style="width: 50%;">4 niałe diody LED</td>
</tr>
<tr>
<td style="width: 50%;">Typ panelu sterującego</td>
<td style="width: 50%;">3.5&#8243; LCD dotykowy ekran</td>
</tr>
<tr>
<td style="width: 50%;">Zakres pracy fal</td>
<td style="width: 50%;">400-550nm (440~460nm peak)</td>
</tr>
<tr>
<td style="width: 50%;">Czas życia lamp</td>
<td style="width: 50%;">50,000 Hours</td>
</tr>
<tr>
<td style="width: 50%;">Regulowana<br />
intensywnośc</td>
<td style="width: 50%;">I, II, III</td>
</tr>
<tr>
<td style="width: 50%;">Intensywność<br />
światła na<br />
każdym poziomie</td>
<td style="width: 50%;">
<p>57 μw/cm2/nm at distance 35cm</p>
<p>49 μw/cm2/nm at distance 40cm</p>
<p>36 μw/cm2/nm at distance 50cm</p>
</td>
</tr>
<tr>
<td style="width: 50%;">Typ licznika<br />
czasu terapii</td>
<td style="width: 50%;">0-999h czas terapii<br />
48h timer</td>
</tr>
<tr>
<td style="width: 50%;">Poziom hałasu</td>
<td style="width: 50%;">&lt;30 db</td>
</tr>
<tr>
<td style="width: 50%;">Wentylator</td>
<td style="width: 50%;">System chłodzenia bez wentylatora</td>
</tr>
</tbody>
</table>
<h3>Warunki pracy</h3>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 50%;">Temperatura</td>
<td style="width: 50%;">15 to 30°C</td>
</tr>
<tr>
<td style="width: 50%;">Wilgotność</td>
<td style="width: 50%;">5 to ≤99% RH</td>
</tr>
</tbody>
</table>
<h3>Napięcia</h3>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 50%;">Voltage and frequency</td>
<td style="width: 50%;">220-240 VAC 50/60 Hz or customer specified</td>
</tr>
</tbody>
</table>
<h3>Przechowywanie</h3>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 50%;">Temperatura</td>
<td style="width: 50%;">-10 to +40°C</td>
</tr>
<tr>
<td style="width: 50%;">Wilgotność</td>
<td style="width: 50%;">0 to 90% RH</td>
</tr>
</tbody>
</table>
<p>Artykuł <a href="https://medleader.pl/ofn-02-lampa-mobilna-do-fototerapii/">Lampa LED do fototerapii noworodków</a> pochodzi z serwisu <a href="https://medleader.pl">Wyposażenie medyczne, Narzędzia chirurgiczne</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Stanowisko pielęgnacji noworodka z promiennikiem</title>
		<link>https://medleader.pl/noworodkowy-ogrzewacz-podczerwieni/</link>
		
		<dc:creator><![CDATA[lukasz]]></dc:creator>
		<pubDate>Tue, 22 Jan 2019 13:17:18 +0000</pubDate>
				<category><![CDATA[Inne urządzenia medyczne]]></category>
		<category><![CDATA[Neonatologia]]></category>
		<category><![CDATA[Strona główna sekcja 1]]></category>
		<category><![CDATA[Urządzenia medyczne]]></category>
		<category><![CDATA[fototerapia]]></category>
		<category><![CDATA[ogrzewacz noworodka]]></category>
		<category><![CDATA[ogrzewanie noworodka]]></category>
		<category><![CDATA[promiennik noworodkowy]]></category>
		<category><![CDATA[promiennik podczerwieni]]></category>
		<category><![CDATA[stanowisko pielęgnacji noworodka]]></category>
		<guid isPermaLink="false">http://medleader.pl/?p=648</guid>

					<description><![CDATA[<p>Promiennik podczerwony dla noworodka. Promiennik może występować w wersji z lampą do fototerapii. Bardzo mobilny. Czytelny wyświetlacz z menu w języku polskim. </p>
<p>Artykuł <a href="https://medleader.pl/noworodkowy-ogrzewacz-podczerwieni/">Stanowisko pielęgnacji noworodka z promiennikiem</a> pochodzi z serwisu <a href="https://medleader.pl">Wyposażenie medyczne, Narzędzia chirurgiczne</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1>Noworodkowy ogrzewacz podczerwieni</h1>
<h2>Stanowisko pielęgnacji noworodka z lampą IR</h2>
<h4>Ecosy 630 Ogrzewacz Noworodkowy</h4>
<h4>Podstawowa konfiguracja:</h4>
<p><img loading="lazy" decoding="async" class="wp-image-1343  alignleft" src="https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-1024x572.jpg" alt="" width="299" height="167" srcset="https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-1024x572.jpg 1024w, https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-300x167.jpg 300w, https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-768x429.jpg 768w, https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-1536x857.jpg 1536w, https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-150x84.jpg 150w, https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-1080x603.jpg 1080w, https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-1200x670.jpg 1200w, https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3-600x335.jpg 600w, https://medleader.pl/wp-content/uploads/2019/01/zdjecie-whatsapp-2025-04-03-o-103804-4b2cb9c3.jpg 1600w" sizes="(max-width: 299px) 85vw, 299px" /></p>
<ul style="list-style-type: disc;">
<li>rura grzewcza kwarcowa dalekiej podczerwieni</li>
<li>Tryby: dla dziecka, ręczny i podgrzewania wstępnego</li>
<li>APGAR i CPR</li>
<li>przezroczyste barierki ochronne z czterech stron</li>
<li>Kąt nachylenia łóżeczka dziecięcego od 0-13 stopni</li>
</ul>
<h4>Konfiguracja opcjonalna: </h4>
<ul style="list-style-type: disc;">
<li><img loading="lazy" decoding="async" class="size-medium wp-image-1453 alignright" src="https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-xray2-282x300.jpeg" alt="" width="282" height="300" srcset="https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-xray2-282x300.jpeg 282w, https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-xray2-141x150.jpeg 141w, https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-xray2.jpeg 573w" sizes="(max-width: 282px) 85vw, 282px" />Szuflada do przechowywania</li>
<li>Kaseta X-ray</li>
<li>Stojak podnoszący</li>
</ul>
<p><img loading="lazy" decoding="async" class="size-medium wp-image-1452 alignright" src="https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-xray1-300x294.jpeg" alt="" width="300" height="294" srcset="https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-xray1-300x294.jpeg 300w, https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-xray1-150x147.jpeg 150w, https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-xray1.jpeg 585w" sizes="(max-width: 300px) 85vw, 300px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h4>Moduł głowicy grzewczej</h4>
<ul style="list-style-type: disc;">
<li><img loading="lazy" decoding="async" class="size-medium wp-image-1450 alignright" src="https://medleader.pl/wp-content/uploads/2025/06/ecosy630-infant-warmer-300x247.jpg" alt="" width="300" height="247" srcset="https://medleader.pl/wp-content/uploads/2025/06/ecosy630-infant-warmer-300x247.jpg 300w, https://medleader.pl/wp-content/uploads/2025/06/ecosy630-infant-warmer-768x632.jpg 768w, https://medleader.pl/wp-content/uploads/2025/06/ecosy630-infant-warmer-150x123.jpg 150w, https://medleader.pl/wp-content/uploads/2025/06/ecosy630-infant-warmer-600x494.jpg 600w, https://medleader.pl/wp-content/uploads/2025/06/ecosy630-infant-warmer.jpg 802w" sizes="(max-width: 300px) 85vw, 300px" />LED wyświetlacz</li>
<li>Łatwa obsługa urządzenia i sprawdzanie informacji.</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1451" src="https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-300x136.jpeg" alt="" width="300" height="136" srcset="https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-300x136.jpeg 300w, https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-150x68.jpeg 150w, https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer-600x272.jpeg 600w, https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer.jpeg 740w" sizes="(max-width: 300px) 85vw, 300px" /></p>
<p>Wielofunkcyjny wspornik barierki bocznej</p>
<p>Możliwośc zawieszenia zewnętrznej lampy obserwacyjnej, urządzenia do fototerapii LED, urządzenia resuscytacyjnego, urządzenia ssącego, mieszalnika O2 i powietrza itp.</p>
<table>
<tbody>
<tr>
<td width="187">
<p>Heater capacity</p>
</td>
<td width="520">
<p>500W</p>
</td>
</tr>
<tr>
<td width="187">
<p>Temperature control</p>
</td>
<td width="520">
<p>Servo (Baby) Mode/ Manual/ Preheating mode</p>
</td>
</tr>
<tr>
<td rowspan="2" width="187">
<p>Baby control mode</p>
</td>
<td width="520">
<p>Setting range: 34.0～38.0℃</p>
</td>
</tr>
<tr>
<td width="520">
<p>Display range: 20.0～42.0℃</p>
</td>
</tr>
<tr>
<td rowspan="2" width="187">
<p>Manual control mode</p>
</td>
<td width="520">
<p>Setting range: 0～100% (in 5% increments)</p>
</td>
</tr>
<tr>
<td width="520">
<p>Indication range: 0～100% (in 1% increments)</p>
</td>
</tr>
<tr>
<td rowspan="2" width="187">
<p>Timer</p>
</td>
<td width="520">
<p>APGAR mode /CPR mode switchable        </p>
</td>
</tr>
<tr>
<td width="520">
<p>APGAR Beep: 1, 5, 10 min.</p>
</td>
</tr>
<tr>
<td width="187">
<p>Display</p>
</td>
<td width="520">
<p>LED digital display</p>
</td>
</tr>
<tr>
<td rowspan="2" width="187">
<p>Bed tray</p>
</td>
<td width="520">
<p>Inclination angle (back and forth) : ±13°</p>
</td>
</tr>
<tr>
<td width="520">
<p>Mattress surface: 500 X 700 X 25mm</p>
</td>
</tr>
<tr>
<td width="187">
<p>Dimension</p>
</td>
<td width="520">
<p>840(L)*1100(W)*1790 (H) mm</p>
</td>
</tr>
<tr>
<td colspan="2" width="707">
<p><strong>Funkcje opcjonalne</strong></p>
</td>
</tr>
<tr>
<td colspan="2" width="707">
<p><strong>X-ray cassette </strong></p>
</td>
</tr>
<tr>
<td width="187">
<p>Wymiary</p>
</td>
<td width="520">
<p>53 X 35cm</p>
</td>
</tr>
<tr>
<td width="187">
<p><strong>Regulacja wysokości</strong></p>
</td>
<td width="520">
<p>Up to 20 cm</p>
</td>
</tr>
<tr>
<td colspan="2" width="707">
<p><strong>Przechowywanie</strong></p>
</td>
</tr>
<tr>
<td width="187">
<p>Temperature</p>
</td>
<td width="520">
<p>-25～60° C</p>
</td>
</tr>
<tr>
<td width="187">
<p>Humidity</p>
</td>
<td width="520">
<p>0～95% RH</p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><a href="https://medleader.pl/wp-content/uploads/2019/01/ecosy630-infant-warmer.pdf">KARTA KATALOGOWA _ Ecosy630 infant warmer</a> </p>
<p>Artykuł <a href="https://medleader.pl/noworodkowy-ogrzewacz-podczerwieni/">Stanowisko pielęgnacji noworodka z promiennikiem</a> pochodzi z serwisu <a href="https://medleader.pl">Wyposażenie medyczne, Narzędzia chirurgiczne</a>.</p>